Source: Mitsubishi Heavy Industries, Ltd.
MHI Thermal Systems to Launch "MSV2" Lineup of Air-cooled Heat Pump Chillers, Including New 70HP Model
- Among Industry's Highest Efficiency Ratings, Adoption of R32 Refrigerant -

- Proprietary technologies result in industry's highest energy consumption efficiency (COP) ratings, enabling significant energy savings
- Adoption of R32 refrigerant with lower charging volume, to meet needs for low GWP
- Space-saving 70HP model added, among industry's largest

TOKYO, Dec 25, 2019 - (JCN Newswire) - Mitsubishi Heavy Industries Thermal Systems, Ltd. (MHI Thermal Systems) is to commence marketing of the "MSV2" series of air-cooled heat pump chillers(1) offering outstanding efficiency and robust capacity to curb global warming. The new models realize the industry's highest levels of coefficient of performance (COP)(2) ratings, a measure of energy consumption efficiency, through the adoption of a newly developed "e-3D" scroll compressor in combination with other proprietary technologies. The new units also adopt the R32 refrigerant featuring a low global warming potential (GWP)(3). Adoption of the MSV2 chillers for air cooling/heating in office buildings or for water chilling/heating in factories enables significant energy savings. Plans call for market launch of four models in summer 2020, in a range from 40 to a new 70 horsepower (HP).

The 60HP and 70HP models have respective COP ratings of 3.46 and 3.33 (rated cooling capacity), the highest levels in the industry(4). As a result, the 60HP model no longer requires registration under Japan's High-Pressure Gas Safety Act. Adoption of the R32 refrigerant (675 GWP), already widely used in residential air conditioners, in place of the earlier R410A (2090 GWP) has reduced GWP to approximately one-third, combined with a 28% reduction in refrigerant charge volume. Together these improvements result in a 77% lower CO2 conversion factor, thereby contributing to the reduction of environmental load. The addition to the lineup of a 70HP model enables space savings even in applications requiring installation of multiple units.

The compressor adopted in the new MSV2 models features a more advanced "e-3D" scroll, which compresses both vertically and horizontally and thereby enhances efficiency during low loads. Changing the shape of the scroll has reduced leakage loss significantly and further raised the efficiency level. Meanwhile, superlative energy-saving performance has been achieved through the adoption of a large fan, long bell mouth, and small-diameter hairpin in the air heat exchanger. In addition, startup speed has been increased threefold compared to earlier models, resulting in reduced fluctuations in water temperature and enabling recovery from power outages. Also, cooling/heating is possible even in extremely hot environments, accommodating outside air intake temperatures up to 52degC.

Going forward, MHI Thermal Systems will continue to pursue the development of technologies and products that contribute to further energy savings and enhanced environmental performance. With its comprehensive technological capabilities derived from synergies enabled by the company's broad operations in fields related to heating and cooling, MHI Thermal Systems will strive for the optimal thermal solutions to meet customers' diverse needs.

(1) A heat pump chiller is a unit that creates and supplies hot and cold water to office buildings and industrial facilities such as factories for air-conditioning and other applications. Heat pump chillers are used mainly in cooling applications, but as the term "heat pump" indicates, they also can serve to heat water to high temperatures. They consist of circuitry using a refrigerant and water circulation system. The refrigerant and water perform heat exchange through a water heat exchanger.
(2) COP: Rated refrigeration capacity (kW) divided by power consumption (kW), including auxiliary power. The higher the value, the greater the energy saving. COP is calculated based on guidelines set by Japanese Industrial Standards (JIS).
(3) GWP: The lower the value, the higher the level of environmental performance. CO2 has a GWP of 1.
(4) Based on MHI Thermal Systems' findings as of December 2019. The values shown are estimates for units with rated capacities of 180kW (equivalent to 60HP) and 200kW (70HP) under conditions of 35degC outside temperature, 14degC cooling water inlet temperature, and 7degC cooling water outlet temperature.


Topic: Press release summary
Source: Mitsubishi Heavy Industries, Ltd.

Sectors: Engineering
http://www.acnnewswire.com
From the Asia Corporate News Network


Copyright © 2024 ACN Newswire. All rights reserved. A division of Asia Corporate News Network.


Mitsubishi Heavy Industries, Ltd. Links

http://www.mhi.com

https://www.mhi.com/rss/

https://www.facebook.com/mhi.ltd/

https://twitter.com/MHI_Group

https://www.youtube.com/user/DiscoverMHI

https://www.linkedin.com/company/mitsubishi-heavy-industries/

Mitsubishi Heavy Industries, Ltd.
May 8, 2024 13:27 HKT/SGT
Mitsubishi Heavy Industries Increases Dividends on Back of Historically High FY2023 Results, Releases FY2024 Guidance
May 7, 2024 12:49 HKT/SGT
MHI Agrees to Collaborate with Chiyoda Corporation for Licensing of CO2 Capture Technologies
Apr 29, 2024 17:49 HKT/SGT
SPARX Group Establishes Space Frontiers Second Fund
Apr 29, 2024 17:00 HKT/SGT
MHI Establishes Local Subsidiary "Mitsubishi Heavy Industries Vietnam"
Apr 25, 2024 16:45 HKT/SGT
MHI Begins Operation of SOEC Test Module the Next-Generation High-Efficiency Hydrogen Production Technology at Takasago Hydrogen Park
Apr 18, 2024 16:01 HKT/SGT
Mitsubishi Heavy Industries and NGK to Jointly Develop Hydrogen Purification System from Ammonia Cracking Gas
Apr 12, 2024 13:39 HKT/SGT
Heidelberg Materials North America Announces Latest Milestone in Edmonton CCUS Project
Apr 11, 2024 17:08 HKT/SGT
MHIAEL Completes Expansion of the its Nagasaki Plant for Manufacture of Aero Engine Combustors
Apr 11, 2024 16:50 HKT/SGT
Mitsubishi Shipbuilding Acquires Approval in Principle (AiP) from Classification Society ClassNK for Ammonia Fuel Supply System (AFSS)
Apr 10, 2024 15:55 HKT/SGT
Mitsubishi Shipbuilding Receives Order for Ammonia Fuel Supply System for Ammonia-Powered Marine Engine
More news >>
 News Alerts
Copyright © 2024 ACN Newswire - Asia Corporate News Network
Home | About us | Services | Partners | Events | Login | Contact us | Privacy Policy | Terms of Use | RSS
US: +1 214 890 4418 | Beijing: +86 400 879 3881 | Hong Kong: +852 8192 4922 | Singapore: +65 6549 7068 | Tokyo: +81 3 6859 8575

Connect With us: